Sign In | Join Free | My isp.org.cn
China China World Technology Medical Equipment Service Group logo
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group Win-win together!
Verified Supplier

5 Years

Home > ECG Machine Parts >

Comen CM1200B ECG Machine Mainboard COMEN_ECG_ARM_9_V1.27_A CM1200B_BOTTOM_BOARD_E

China World Technology Medical Equipment Service Group
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Comen CM1200B ECG Machine Mainboard COMEN_ECG_ARM_9_V1.27_A CM1200B_BOTTOM_BOARD_E

Brand Name : Comen

Model Number : CM1200B

MOQ : 1 Piece

Price : USD

Payment Terms : T/T,Western Union,Paypal

Delivery Time : 3-5 working days

Packaging Details : Carton

Product Name : Mainboard

Model : COMEN_ECG_ARM_9_V1.27_A CM1200B_BOTTOM_BOARD_E

Condition : Used-good

MOQ : 1 Piece

Type : Spart parts

Material : Metal

Color : Green

Delivery Motheds : DHL/Fedex

Warranty : 90 Days

More Details : Contact CWT Technology HK Limited

Contact Now


Comen CM1200B ECG machine mainboard COMEN_ECG_ARM_9_V1.27_A CM1200B_BOTTOM_BOARD_E



Product Describe

Comen CM1200B electrocardiograph motherboard, model number is COMEN_ECG_ARM_9_V1.27_A CM1200B_BOTTOM_BOARD_E. The motherboard is the brain of the electrocardiograph and bears vital responsibilities. It can process various data collected by the device, transmit signals to various key accessories, and perform very critical tasks such as control functions. It is a key accessory that determines the stability and accuracy of the ECG machine.



Product features

1. Multi-lead signal processing

The mainboard of Comen CM-1200B can efficiently process 12-lead ECG signals at the same time. It can also amplify, filter, convert and process the electrical signals collected by the leads from various parts of the human body, and present the converted ECG clearly and accurately for medical staff to refer to, which is an important basis for diagnosis.

2. Intelligent data analysis and interpretation

The mainboard has built-in advanced analysis software modules, which can perform intelligent analysis on the processed ECG data. It can automatically identify various types of arrhythmias, such as premature beats, atrial fibrillation, ventricular tachycardia, etc., and give preliminary diagnostic suggestions to improve diagnostic efficiency.

3. Equipment function control

Fully responsible for the control and coordination of various functions of the CM1200B ECG machine. Including controlling the display content on the display screen, such as real-time display of ECG waveforms and switching of menu operation interfaces; managing the printing tasks of the built-in thermal printer to ensure that the printed ECG reports are clear and standardized to meet the diverse clinical needs.

4. Data storage and transmission

The mainboard has an internal storage capacity of 300 ECG records, which allows medical staff to view historical data at any time and compare the patient's condition. At the same time, it is equipped with a USB interface for connecting to an external printer for report printing, and can also realize data transmission to external devices such as computers.



Products Parameters

Product Name

Mainboard

Model

COMEN_ECG_ARM_9_V1.27_A,CM1200B_BOTTOM_BOARD_E

Applicable machine

Comen CM1200B ECG Machine

Storage capacity

300 ECG records

Data transmission interface

USB interface, supports data transmission and external printer

Operating Temperature range

0℃ - 40℃

Signal processing capabilities

Process 12-lead ECG signals simultaneously, with adjustable amplification and high filtering accuracy

Analysis capabilities

Automatically identify various arrhythmias and measure various ECG parameters



FAQ​

Q1: After replacing this motherboard, do I need to recalibrate the ECG machine?

A1: After replacing the new motherboard, it is recommended to fully calibrate the ECG machine. Because the signal processing characteristics of the new motherboard may be slightly different from the old motherboard, calibration can ensure that the measurement accuracy of the device is restored to the best state and the accuracy of ECG signal measurement is guaranteed.

Q2: After the motherboard software is upgraded, will the original data storage be affected?

A2: Under normal circumstances, the motherboard software upgrade program officially released by Comen has been strictly tested and will not affect the original data storage. The upgrade process mainly updates the analysis algorithm and function optimization of the motherboard, and will not overwrite or delete the ECG data stored in the motherboard storage chip. However, for the sake of insurance, it is recommended to back up important ECG data to an external storage device through the USB interface before upgrading the software.

Q3: The motherboard suddenly heats up severely during use. What may be the reason?

A3: The motherboard heats up severely due to a variety of reasons. One is that the device is used continuously for a long time and the heat dissipation is poor. For example, if the device is placed in an unventilated environment, or the cooling fan fails, the device placement environment should be checked and the cooling fan should be operated normally. Second, there may be a component short circuit failure on the motherboard. In this case, professional technicians need to use detection equipment to check and replace the faulty component in time after determining it.



Product Picture

Comen CM1200B ECG Machine Mainboard COMEN_ECG_ARM_9_V1.27_A CM1200B_BOTTOM_BOARD_E

Comen CM1200B ECG Machine Mainboard COMEN_ECG_ARM_9_V1.27_A CM1200B_BOTTOM_BOARD_E










Product Tags:

CM1200B ECG machine mainboard

      

Comen CM1200B mainboard

      

Comen CM1200B ECG Machine Mainboard

      
Cheap Comen CM1200B ECG Machine Mainboard COMEN_ECG_ARM_9_V1.27_A CM1200B_BOTTOM_BOARD_E wholesale

Comen CM1200B ECG Machine Mainboard COMEN_ECG_ARM_9_V1.27_A CM1200B_BOTTOM_BOARD_E Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: China World Technology Medical Equipment Service Group
*Subject:
*Message:
Characters Remaining: (0/3000)